$2,999.00

Qty:

By Raypak


Details

Top

Model # 009217

Warranty 1 Year

Manufacturer Code P-R266A-EN-C #50

Alternate Part #'s 009217, P-R266A-EN-C #50, PR266AENC, RAY009217

Product Description

Think about being able to use your pool or spa at the perfect comfort level even when Fall arrives...or when the first chill of Winter is felt in the wind...or in the Spring or Summer when evenings can turn chilly in a minute!  Helping you get more enjoyment from your pool or spa is the smart idea behind the Raypak heaters.

BENEFITS:

  • Digital control with liquid crystal display (LCD) for temperature selection and heater settings

  • Capron resin headers prevent rust stains from harming pool surface

  • Plumb directly from provided 2" PVC threaded union

  • Smart microprocessor controls diagnostic read-out and continuously monitors operating status

  • Completely field serviceable

  • Small footprint

  • High efficiency

  • Guaranteed high wind reliability

  • Looks smart and works smart

  • Thermal Efficiency of 83% 

  • 1 Year Warranty

Elevation: 0 Ft. – 2000 Ft. Click Here for High Altitude Pool Heaters

    

California Customers Please Note:  South Coast Air Quality Management District (SCAQMD) Area of Jurisdiction REQUIRES a Low Nox Heater be installed.  The following 6 California Counties are affected:  Los Angeles, San Bernardino, Ventura, Orange, Riverside, & Kern. Installing a non-compliant heater in these counties will void the manufacturer's warranty and could result in a fine from your local code enforcement.    

Click here for RayPak Low Nox Heaters

Dimensions:

Raypak Pool Heater DimensionsRaypak Pool Heater Dimensions

Raypak Heater Dimensions

Warranty:

WARRANTY EXCLUSIONS 
This Limited Warranty does NOT apply; 
1. if the product has been moved from its original place of installation, or if the original 
owner no longer owns the property where the original installation was made; 
2. if the product is not properly installed with a pool or spa by a qualified licensed installer in 
accordance with applicable local codes and ordinances, good trade practices, and the 
manufacturer’s installation instructions; 
3. if the rating plate(s) or serial number(s) are altered or removed; 
4. if the product is modified in any way, or non-factory authorized accessories or other 
components are used in conjunction with the product; 
5. to damage, malfunctions or failures resulting from failure to properly install, operate or 
maintain the product in accordance with the manufacturer’s instructions; 
6. to damage, malfunctions or failures from abuse, act of nature, accident, fire, flood, freeze, 
lightning or the like; 
7. to damage, malfunctions or failures resulting from [or due to] connected system control 
devices; 
8. performance problems caused by improper sizing of the heater or electric service 
voltage, wiring or fusing; 
9. use of any attachment, including any energy saving device not authorized by the 
manufacturer. 
10. to damage, malfunctions or failures from misuse or neglect, including but not limited to, 
freeze-ups, operating the heater with the cabinet door off, having flow restrictions or 
obstructions between the heater outlet and the pool/spa, or not maintaining a proper 
chemical balance (PH level must be between 7.4 and 7.8 and total alkalinity between 100 
and 150 PPM. Total dissolved solids (TDS) must be no greater than 3000 PPM)

Product Specifications

BTU:
266,000 BTU
Ignition:
Electronic
Digital Readout:
Yes
Notes:
0-2000 ft elevation
Elevation:
0-2,000 ft.
Heat Exchanger:
Copper
Heater Type:
Natural Gas
Manufacturer:
Raypak
Top

?     Asked on 1/16/2012by Guest

Will a gas heater operate at the low speed of a dual speed motor?
 Reply

A  Answered on 1/16/2012 by InyoPools Product Specialist Patrick P.

Probably not - Most gas heater will shut off at low GPM levels (20-40) to keep the heater cores from overheating - 20 for 200 BTUs, 40 for 400 BTUs. Depending on your pool system you might get these GPM levels at the low speed but generally these heaters must be run at the motor's high speed.
 Reply


?     Asked on 10/10/2012by Guest

What is the difference between an Electronic and Millivolt ignition?
 Reply

A  Answered on 10/10/2012 by InyoPools Product Specialist Patrick P.

The basic answer is that Millivolt is the old style of ignition, using a standing pilot light. While the electronic ignition uses a spark start system like a gas grill. Electronic ignitions are more efficient in gas usage and also are better suited for high wind areas where a pilot light might get extinguished.
 Reply


?     Asked on 1/6/2015by Suljo

Can you get a remote control for the Raypak 266000?
 Reply

A  Answered on 1/6/2015 by InyoPools Product Specialist Robert M.

Hello Suljo - You could use something like the Intermatic PE653RC to remotely control the Raypak heater.
 Reply


?     Asked on 4/2/2015by Therese

Hi, I wondered how high I can turn up the heat on the Raypak 266? My last heater, a Hayward, only went up to 90, and I don't believe the actual water temp ever got near that. Hopefully, I won't need to turn it so high, but there are always a few cool evenings when I like to crank it up. Thanks.
 Reply

A  Answered on 4/2/2015 by InyoPools Product Specialist Lennox H.

Therese, these units are factory set for a max temperature of 104 degrees. A licence contractor can adjust it to 107 degrees max following Raypak instructions.
 Reply


?     Asked on 4/30/2015by Inyo Visitor

Is this heater available above 2,000 feet?
 Reply

A  Answered on 5/1/2015 by InyoPools Product Specialist Patrick P.

This particular model is good for 0' - 1,999' we do have our Raypak High Altitude Heaters which go from 2,000' - 9,000' so I would suggest the high altitude model.
 Reply


Top
Difficulty

Est. Repair Time

4 to 8 hrs

Tools Needed

Screwdriver, Pliers, saw to cut pvc pipe, pipe wrenches,

7     0

After nearly 20 years of reliable service my old RP2100 gave up

Written on 7/4/2019 by Guest

Disconnect gas, electric, and pvc water pipes.

Remove old heater

Clean area

Position new heater.

Reconnect services. Note: Electrical connection was same. Had to install new water in/out piping due to cutting out old piping.

Startup according to instructions

You will need help removing old and positioning new heater. They are heavy.

As for services, I was lucky in that I had to do little fabrication. This heater was very similar to my old one. Make sure to confirm location of all connection.

This is NOT a difficult task IF you are comfortable working with gas, electricity, and PVC plastic pipe.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

2 to 4 hrs

Tools Needed

Screwdriver, Nut Drivers, Pliers, Adjustable Wrench

2     1

Heat exchanger leak

Written on 8/9/2018 by Guest

Discover leak. Order new heater. Order pipe fitings. Buy gas pipe fittings, remove old heater. Place new heater. Install power lines. Connect gas lines. Connect water lines. Test.

Were these instructions helpful? 
 

Top

Review Summary

 (Average 4.73  out of 5 stars)
33 Rating
5 star:
 
(27)
4 star:
 
(5)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(1)

The Most Helpful Review


The Most Recent Reviews